[1.6.5] with RTE 3.20 FIX: Update 1.6.4 could cause problems when the "Big Font" default view was preset to "Decoplan". The menu entry "Big Font" in SYS2 could freeze the OSTC4 in surface mode
[1.6.4] with RTE 3.20 CHG: Deactivation of the 'fallback' option when the CCR mode is set to 'Fixed' - this makes it a little clearer that the option has no influence in this mode. NEW: CCR overview in surface mode. Makes it easy to quickly check that all settings (mode, setpoints, diluent, scrubber timer) are correct when preparing to dive (also makes the OC gas list available in surface mode for the same reason). CHG: Revised automatic setpoint change. The proposed approach is essentially the approach used by most controllers of eCCR ('upshift' on descent, 'downshift' on ascent), so that the OSTC4 when used as a backup computer for eCCR will make the changes at the same time as the eCCR itself. CHG: Enhancements with the compass. Delete bearing and reset to land based bearing, Add support for a configurable compass declination in a range of -99 to 99 degrees. NEW: Added UART multiplexer support for DiveO2: The existing autodetect function now includes a UART multiplexer. The datastructures and protocol handling has been adapted to support several DiveO2 sensors connected to the UART. NEW: Define explicit setpoints for low / high / deco. Add an option to delay the switch to SPlow until all decompression has been cleared. NEW: Adds a simple countdown timer, available as a custom view in surface and dive mode. This can be used to time safety stops, or to prebreathe a CCR (or to boil your breakfast eggs if you are so inclined). The duration of the timer is configurable from 1 second to 9:59 minutes in the System menu. The timer is started by switching to the custom view, and remaining on it until a 10 second delay has elapsed. Once the timer has started the custom view can be changed and the timer will continue running in the background. After the timer has run out 'Finished' will be shown for 10 seconds in the timer custom view, and then automatic switching of custom views (if configured) resumes. In surface mode the dive computer will not go to sleep while the timer is running, and a mini timer will be shown when the timer custom view is not showing. Fix: Fix a bug that disables arbitrary menu lines in dive mode if lines are disabled / inactive in surface mode. Fix: Bugfix CustomView selection during dive mode: The CustomView selection during dive mode was limited to two pages, while meanwhile three are needed to show all options. The problem did not showup in surface mode selection. Rootcause was a static definition instead of the dynamic one used in surface mode. In addition with every page shift a new page was created which might cause display errors after some times. To solve this the pages are now updated instead of rebuilding the pages.
[1.6.2] with RTE 3.10 CHG: Allow dates >2022 to be set in the menu NEW: Support for DiveO2 Solid-State-Oxygen sensor NEW: Sensor autodetect allows combination of one solid-state sensor and up to two analog sensors FIX: Bugfix compass bearing: In previous version an invalid value was set in case the bearing was set without compass calibration. Rootcause was that the bearing -1 is received in case the compase is not calibrated. This has been fixed by setting bearing to 0 (360) in that case. NEW: Extension scrubber time: In previous version only one scrubber timer was available. After movement of scrubber timer menu menu space became available allowing to upgrade the functionality to support two scrubbers. To make it easier to identify combination ID to used scrubber the date of the last usage of the scrubber timer has been added. NEW: Added new info page for extended sensor data: The new source file may be used to create a information page individual for every smart sensor type. The DiveO2 sensor is the first supported sensor NEW: Show saturation in large font view: In case the DecoTTS custom view is active then the saturation will be displayed if the diver is close to the surface (TTS < 1 minute). FIX: invalid setpoint (0.0) was used after switch from CCR to extra (OC) gas NEW: Add mini compass with marker declination indication selectable in dive mode NEW: Enable start dive in Big font display: The diver had to manually switch to the big font view in dive mode. By selecting the big font view as default view in the custom menu the BF view will now be shown from the start of the dive. In order to have a qucker access to the settings menu, the settings menu has been added to the quick menu selection. The settings menu will then also be left to the BF view. NEW: Added button lock after wakeup in surface mode: During setup of diveequipment the OSTC4 is sometimes operated unintended (e.g. while equipping the jaket). To avoid this it is now possible to activate a button lock in the button lock sensitivity menu. The OSTC4 will then wakeup as usual but if the diver wants to oerate the menus he has to press the buttons in a certain order. The button to be pressed is indicated by a blue bar. The button lock is deactivated in dive mode. NEW: Quit simualted dives after the dive time set in the SIM tab. NEW: After a firmware update, use the factory settings for button sensitivity if these exist, the default settings otherwise. The factory settings for the buttons can be updated in the System menu / Reset menu / Maintenance / 'Store button factory defaults'.
[1.6.0] with RTE 2.09 FIX: automatic switch to o2 sensor custom view: In surface mode the custom view will automatically switch to the o2 sensor view in case the OSTC4 is set to sensor mode. This was also done in case the o2 sensor view was deactivated. This lead to a automatic switch to e.g. compass what was not intended. In the new version the automatic switching is deactivated in case the custom view is deactivated CHG: Ignore automatic setpoint changes during ascend: In the previous version setpoint changes which have been configured for descending were considered for deco calculation in case one or more additional diluents have been activated. This procedure does not fit to the common way to keep setpoint high till end of the dive in order to get rid of the deco time. In the new implementation the OSTC 4 assumes that the current setpoint is used till the end of the dive. FIX: Bugfix low ppO2 warning in bailout mode: the code has different sources for divesettings (real and simulated). The ppo2 calculation code used the pointer to the real structure. As result in simulation mode an error occured caused by the ppo2 calculation which was not aware that a bailout happened (because the real structure was references instead of the simulator ones). The problem has been fixed by using the "stateUsed" pointer which is refering to the structure currenty in use. FIX: Battery charge complete event: In previous version it could happen that the battery charge state was set to 100% even the battery was not completly charged. Rootcause was that the external charger IC signals sometimes completion because e.g. the connection between charger unit and OSTC is disconnected within a short time slot. This may happen while the user is trying to get the OSTC in a good charging position. To avoid this the state machine now checks the voltage everytime for valid charging complete range before a charging complete is signaled.
[1.5.9] with RTE 2.07 NEW: Added Charging view: In case the charger is connected to the OSTC a new menu will be shown in the customer view section. The new view shows a charging current indicator, the current charge percentage and an estimation how long the completion of the charging cycle will take (hour window). NEW: PSCR Mode NEW: Scrubber Timer tracks use of CCR scrubber CHANGE: Allow setpoint starting at 0.4 ppO2: Some rebreathers (e.g. Sentinel) start with a ppO2 of 0.4 Bar => modified range check to allow this value (was 0.5 before) NEW: Introduced new menu tab "OP" for additional CCR options, e.g. The Scrubber timer and PSCR parameters
[1.5.6] with RTE 2.06 NEW: O2 calibration for analog sensors FIX: At the begin of the dive and while switching between T7 <=> T3 view a primary view could be shown which was deactivated by the selection dialogue. In case the primary view is now deactivated, the next activated view will be shown instead FIX: Compass accuracy for some hardware versions CHG: Handle analog O2 sensor voltages outside reasonable parameters as invalid CHG: In surface mode the custom view will now reset to the o2 sensor display if sensors are connected and no button has been pressed for 20 seconds
[1.5.5] with RTE 2.05 NEW: SYS3 menu where all custom views can be configured in detail (center, corner and big font) FIX: Disable compass properly when not in use (end-2019 hardware only) NEW: Added new option to gas configuration: "Off" (These are then not shown in the custom gas list) FIX: Startup behaviour in cases where incorrectly stored dives are in the internal logbook
[1.5.4] with RTE 2.04 FIX: support for some old harwdare versions was broken in 1.5.3 (Only serial number <100 were affected) CHG: layout in internal logbook cleaned CHG: Only switch between "no fly" and "desaturation" in case there is desaturation time left FIX: Balance value of button responsitivness were not considered during firmware startup CHG: internal improvements in sleep mode FIX: use dummy profile if necessary (If there are corrupted dives in the logbook)
[1.5.3] with RTE 2.03 CHG: Always show battery voltage in surface mode CHG: battery status is now preserved for future updates NEW: Support for much faster updates (With OSTC companion 3.2 and later) FIX: (very) short screen lag removed during sample storage in dive mode
[1.5.2] with RTE 2.02 Beta Version! FIX: display of time of minimum voltage FIX: Display of Sensor values. At divestart sensor values were shown even sensors were deactivated (fix SP) FIX: Bugfix invalid voltage / temperature after coldstart FIX: Instant dive start at several meters out of sleep mode (Jumping into the water) may resulted in lagged/freeze depth reading CHG: Speed increase of Bluetooth communications CHG: Look and Feel for Gauge/Apnea mode with flipped screen improved FIX: Deco warning after Gauge mode FIX: Download issues of corrupted dives FIX: Proper logbook write (Very spurious error, mainly in CCR mode)
[1.5.1] with RTE 2.01 NEW: Support for end-2019 Hardware
[3.24] MD5: fc65c6b668dc87b36576a330f5bb3189 CHANGE: Add voltage-based battery meter for OSTC+/PLUS when inserting batteries with unknown SOC CHANGE: Compatibility for new hardware versions CHANGE: Language updates BUGFIX: Release and "Update" dates fixed
[3.22] MD5: 9a86e4c2452b55a4dc9a043fbfa1ca71 FIX: minor fix of 12h time update in dive mode NEW: Add charge cycle counter NEW: Add surface customview 11: NoFly, Desat and CNS NEW: Show # of descends in Apnoe mode CHANGE: Compatibility for new hardware versions CHANGE: do not show the "slow" in the alternative layout CHANGE: minor adjustment of depth position in large layout
[3.21] MD5: 62eae67e83fd5527cc205b8acbc37bf6 FIX: Wrong release date in 3.20 showed "Update!" message prematurely CHANGE: Compatibility for new hardware versions CHANGE: Reduce default bottom time for simulator from 10' to 2' FIX: BLE was on after first reboot (until sleepmode kicks in)
[3.20] MD5: c0e1430ec55b4f22ef21fc5a71afd0e3 Bugfix: Some USB hardware version showed USB mode insetad of BLE Mode
[3.19] MD5: 9e79db5fa4f2f72086ce83abd3ee279f BUGFIX: Increase resolution of tissue pressure calculations to track very low pressure differences between ambient and tissue pressures CHANGE: OSTC with mechanical (magnetic) buttons need both buttons beeing pressed to wake up CHANGE: Support for new OSTC+ hardware with O2 sensor inputs CHANGE: Adjust max. brightness settings CHANGE: reset planning parameters to default values - only when entering the menu, thus keeping the settings between multiple calculator runs FIX: the output of the calculation results was divided into several steps, which could be interrupted in cooperative multitasking. So glitches could occur in the screen output if e.g. the TTS switched to NDL but the deco data flag vector was not updated yet. Now the compilation of all calculation results can no longer be interrupted.
[3.18] MD5: c1720d0eb4b59c411e4dc2fe1862403b BUGFIX: Properly update desaturation time and tissue data after battery change (OSTC with user-replaceable batteries only) NEW: Option to suppress non-critical warnings in dive mode CHANGE: Do not present gas6 option in alternative layout (Switch to normal layout in order to configure the gas 6 during the dive) CHANGE: Do not show RX portions of tank setup menu when there is no RX hardware CHANGE: Low-level code improvements for performance
[3.17] MD5: 7b0dd87a7b7788c947682ad9c54a72a0 NEW: Support for current hardware version of OSTC 2, plus and Sport - a Reset Bluetooth from the Reset Menu might be required for BLE/Bluetooth 4.0 to be enabled
[3.16] MD5: c82632f2d1efcca365f418e72b22cedc BUGFIX: Sensor detection in OSTC plus could fail for some hardware versions BUGFIX: calculate time/date of the end of the dive in logbook screen correctly for dives with a lot of surface time/many descents NEW: Different brightness settings for dive and surface mode NEW: minor changes in the different language versions BUGFIX: Reduce sleep mode current
[3.15] MD5: 9eeca2f8d4295c4b66b1aa69e04705c1 NEW: Support for new pressure sensor type in OSTC 2 and plus NEW: Several changes in the different language versions CHANGE: Tweak gas use routine to work with unplanned changes (Switching to inactive gases) NEW: Big dive mode menu in big layout view BUGFIX: fix pulsing brightness in ECO on some hardware versions CHANGE: support for internal hardware changes CHANGE: adjust gas density parameters to match upcoming new ISO standard
[3.13] MD5: 9c226f0171af384ac9513b64ca15c26f NEW: Support for current hardware version of OSTC 2 and plus FIX: Abort on unknown parameter in comm mode CHANGE: Several small language fixes CHANGE: increase battery safety margins for Saft (T0) and 16650 batteries (T4)
[3.12] MD5: 610b57b2998cfe300a97eab8cd776d18 BUGFIX: Deco paramters (Saturation/Desaturation) were shown false in the logbook and surface screen (Non-GF deco mode only) BUGFIX/CHANGE: Saturation/Desaturation parameters are moved into thier own Sub-menu (Non-GF deco mode only) BUGFIX: Screen startup behaviour (OLED Limited Edition only)
[3.11] MD5: 5f8c1ae3fcd7b53cafcab511656084ce BUGFIX: Surface pressure compensation (zero meter reference) could be delayed or stuck to old reference value BUGFIX: configuring deco gases via the mobile Apps was not possible CHANGE: French language fixes
[3.10] MD5: 3a2e43381ce352f785096810cad19a33 - Hardened all USB/Bluetooth communication against data losses and timeouts - A new Firmware Recovery Feature has been added: the currently active firmware can be backed-up and restored later on while other firmwares have been loaded thereafter. The feature is accessible via Settings -> System Settings -> Reset Menu -> Reboot and becomes available with the first firmware load after the V3.09 beta 4 (or later) is already on the unit. - New option to acknowledge the most recent warning in dive mode (Left press -> Ackn?) - Removed option 'ascent speed', ascent calculation is done with a fixed speed of 10 meters/minute now (equals the ascent speed limit by Bühlmann). - Improved calculation accuracy of the initial ascent. Remark: this will have a slight impact on the resulting deco schedule compared to firmware 3.08. - The deco calculator now figures in the salinity setting. - Aligned logbook and last dive summery of avg and max depth regarding rounding and incorporation of salinity setting. - Done some fine-tuning of depth outputs when using imperial units (feet). - In dive mode, sometimes the temperature was not shown any more after a gas change - fixed now. - The menu system around setting up the dive mode & settings has been decluttered. All settings are now sorted into the groups dive setup, deco setup, SAC (gas needs) setup, ppO2 setup and stops & depths setup. - There is a new option "Swap on empty" in Dive Setup -> SAC Setup. It is only effective if "CalcGas(B/O)" is switched on, too. If both options are switched on, the deco calculation will switch to another tank (i.e. gas) once the tank of the current gas is calculated to be used up. This function can be used to automatically calculate a contingency in case of running out of a deco gas, as the deco calculation will then continue to calculate a deco making use of the spares from the another gases carried. Another application is with two or more tanks holding the same gas (i.e. independent double configuration, side-mount), as the calculations will then take the cumulative amount of gas carried into account before raising a gas needs attention or alarm. - Fixed the urge of the better gas hint to always favor one specific gas out of a set of two or more gases that have the same change depth. - For dives done on firmware >= 3.08 the logbook will have one more page showing the tissue pressures and supersaturation levels as of at the end of dive (i.e. when surfacing). - As long as a gas or diluent is currently selected as breathed, it can not be set into the lost state any more. - When changing the battery or doing a cold start, the current CNS value does not get lost any more. - During loading of a new firmware the clock will not loose time any more (on old firmware it became late by about 15 sec on each firmware update). - When run from a 3.6 V battery (either replaceable or built-in), the surface mode timeout is now extended to 4 minutes before going to sleep mode. If the OSTC is run from 1.5 V disposables, the timeout remains at the previous 90 seconds to save on battery runtime. - Internal improvement: the code for the internal storage system and for the communication system (firmware uploading, dive data downloading) has been re-factored to secure maintainability for the next years to come. - Internal improvement: the scheduler for the dive mode calculation plans (fTTS, bailout) has been completely rewritten for better maintainability.
[3.08] MD5: aa73b8aad928d4a827a97978027ab726 BUGFIX: "Sticky" button behaviour on some hardware versions (Only OSTC 2 (2017), TR and OSTC plus)
[3.07] MD5: 4ee3a98b70f73c1d1aa11d5b91e2f70f BUGFIX: Add surface part at end of dive to surface interval properly BUGFIX: Average depth in logbook did not took salinity setting into account CHANGE: Change color of temperature values in logbook to yellow
[3.06] MD5: 6f6e2bf49297f359459aac2b2a90115a BUGFIX: Hardware versions 13-xx-xx and 58-xx-xx could hang up with single-language versions of 3.03 or 3.05
[3.05] MD5: 2fcfaa793b1bca51cb55f4e068bcd4a3
CHANGE: In the Tech version, max. ppO2 limits can now be adjusted up to 2.0 bar. Caution: know what you are doing! Recommended max settings are 1.4 bar for work gases and 1.6 bar for deco gases. CHANGE: CCR mode diluent ppO2 versus setpoint check can be disabled now. CHANGE: Fine tuning of the better gas cue behavior. CHANGE: Improved smoothing of compass display. NEW: Attention and warning thresholds for gas density put into the options table (adjustment via external software only, no mapping in OSTC menu as of now). CHANGE: Renamed OC gas type 'normal' to 'work' (gas for the working phase of the dive). Along with this, it received a down-arrow symbol to depict it as a gas for use at depth, similar to the '=' symbol that was introduced some time ago to visually depict deco gases (imagine the horizontal lines as deco stops).
EXAMPLE 1: Single gas dive: set gas to use as 'first' and all other gases to 'disabled'.
EXAMPLE 2: Gas-change, extended no-stop dive: set gas to start with to 'first', all other gases to be used later in the dive to 'work' and the unused gases to 'disabled'.
EXAMPLE 3: Deco-dive with one gas for descent & bottom phase, and deco gases: set bottom gas to 'first', deco gases to 'deco' and the unused to 'disabled'.
EXAMPLE 4: Deco-dive with a deco gas used as travel gas on ascent, bottom, and deco gases: configure the deco gas twice: once as travel gas and once as deco dive. Set the same change depths for both instances and put the travel gas before the deco gas in the gas list (i.e: gas 1: travel, gas 2: work (bottom) gas, gases 3-5: deco gases). Set the travel gas to 'first', the bottom gas to 'work', and the deco gases to 'deco'. Take care to adjust the pressure available on the deco gas which is used for travel gas, too, to the amount of gas that is planned to remain after having drawn the travel portion from it!
CHANGE: When ppO2 is above normal threshold, but still inside the deco max threshold, and the dive has not yet progressed to doing the deco stops, the ppO2 warning has been degraded to an attention, i.e. associated messages appear in yellow now instead of red as before. CHANGE: In the simulator, the +5 minutes function can now be triggered in succession without needing to reopen the options menu each time. BUGFIX: Setting the change depth of the first gas to zero caused some unintended behavior. This is captured now. Anyhow, since firmware 3.2 it is required to set proper change depths for gases and diluents, including the ones set as 'first'! CHANGE: The deco calculator now automatically picks the best gas suitable for the set bottom depth. If no suitable gas is found (i.e. configured), calculation will be aborted with an error message. By this change it is possible to calculate dives that use a travel gas (set as 'first') and a bottom gas (set as 'work'), as the deco calculator will now pick the proper bottom gas for calculating the bottom segment. Note: the deco calculator does not calculate the descent phase but actually spends all of the set bottom time at bottom depth. While this puts the deco calculation results on the safe side, beware that the needs on the travel gas will not show up in the gas needs calculation results. CHANGE: OSTC TR: The timeouts for attentions and warnings in connection with discontinued reception of transmitter data have been relaxed a bit: - For up to 2 minutes without updating the last value received will be retained. - After 2 minutes without reception of any updates the pressure value will be marked as outdated. - After 4 minutes without reception of any updates a transmitter will be declared lost. CHANGE: OSTC TR: pressure logging has been implemented. Logged pressure data can be retrieved by downloading the logbook data using external logbook software. CHANGE: Descent speed in the simulator has been increased from 19 to 24 meters per minute. This speed is not configurable, nor the simulator's ascent speed of 9 meters/min! CHANGE: In dive mode, the battery voltage will be shown when reaching 30%, and a warning will be issued when the percentage reaches 25% with 1.5 Volt batteries or 15% with LiIon batteries. CHANGE: Added a hysteresis to the dive start / dive end depth threshold. BUGFIX: Bugfix in none-helium compile variant. NEW: Added an option "extended stops" (named "Gas Change/...before 1.Stop" in Deco Setup -> Deco Parameters -> more). If set to YES, a gas switch will be planned immediately on the change depth of the gas, even if a stop on that depth is not required by deco constraints. When set to NO, the gas switch will be planned to be done on the next regular deco stop. With extended stops enabled and a setting of "Gas Change (time):+0'" the switch will be planned with no actual halt at the change depth (i.e. "switch on the fly"). With change time set to > 0', a dedicated stop will be placed at the change depth for the given number of minutes. This gas change stop may not be needed by deco constraints, but it will influence the following deco stop depths and times as it introduces some added time at depth. CHANGE: Complete rework of the alternative dive mode screen layout. NEW: Included RX firmware update into tech version. CHANGE: Reworked code for ascent and deco stops calculation. Does produce different results compared to the code used in 3.00.3! With this implementation of an GF-controlled deco schedule it becomes visible when deco stops disappear due to a high GF slope (difference between GF low and GF high) combined with a moderate depth of the first deco stop. BUGFIX: When switching between GF and aGF, the depth of the first stop (determined by GF low) will be recalculated now. NEW: New tissue graphics option (compile option as of now): shows absolute tissue pressures (N2 + He added) and saturation per tissue. In the saturation bargraphs, the green line marks GF low position, the yellow line GF high and the red one 100%. BUGFIX: GF low can not be set higher than GF high any more as such a setting would produce an illogical deco schedule. BUGFIX: In case the compass is not calibrated, the heading is now displayed as "---°" instead of ".00°". BUGFIX: In the surface tissue graphics, tissues whose supersaturation exceed 100% are shown in red color now. CHANGE: If any tissue is beyond 100%, no desaturation and no-fly times will be shown anymore. BUGFIX: After use of the dive simulator and the deco calculator the interim tissue desaturation is catched up now. NEW: Added support for display type 2. CHANGE: The Deco Engine has been reworked to now run for up to 700 ms each second (configurable, 800 ms may be feasible also), split into two compute chunks per second. This increases reactivity to buttons presses and compass display, while boosting deco calculation turn- around times significantly. CHANGE: The simulator now uses the current ambient pressure as surface pressure instead of a fixed 1.000 hPa as done before. So in mountain diving, when being at the dive site the simulator will show the same NDL times and deco schedules as will be shown in a real dive. CHANGE: When exiting the surface menu, the return to the normal surface screen has been sped up and the display of the power-up logo screen is skipped now also. CHANGE: When submerged, the unit will now proceed from surface mode display to dive mode display without intermediate display of the power-up logos. NEW: A cue is given when it is time to go up to th next deco stop by highlighting the next stop data until ascent is done. BUGFIX: When being shallower than the indicated stop depth, i.e. because the deco needs to be accelerated, the reduced ambient pressure is figured in into the deco calculations such that the displayed stop time, TTS and gas needs do immediately reflect the reduced depth. BUGFIX: When set to imperial units, all depth will be shown in feet now not only in dive mode but also throughout the whole surface menus. BUGFIX: When in a leap year, the 29th of February is now correctly handled when adjusting time and date on exactly that day. BUGFIX: Bugfix: with the option 'always show ppO2' set, in CCR and pSCR mode a "Dil:x.xx" ppO2 message was sometimes shown twice, once as an info and additionally as an attention or warning. This has been fixed now: in case of an active attention or warning the secondary info message gets suppressed. BUGFIX:: the Simulator +5 min function had a punch-through effect on the real world last dive time (displayed surface interval). BUGFIX: Tissue desaturation is now also computed while in surface and menu modes.
[3.01] MD5: df044192093ca72cab8b6cf00121c706
BUGFIX: Some language corrections BUGFIX: Battery display in internal logbook BUGFIX: Compass issues fixed
[3.00] MD5: c227ac834f57fd831b71378cecaf2a7f
CHANGE: Battery selection menu simplified BUGFIX: Minor language and layout corrections
[2.99]
MD5: 51307831e6874c540ceaf8708ee73c0f
- GF low can not be set higher than GF high any more as such a setting would produce an illogical deco schedule.
- Moved positions of the GF values in the custom view such that 100/100 can be shown without numbers graphically overlapping.
- The resettable stop watch shown in the compass custom view now has both of its digits for the seconds shown as intended.
- As it will always be unknown how much power will exactly be available from a battery, the threshold for a battery low warning has been rised from 10% to 30%. When in dive mode, the display brightness will be set to ECO upon reaching this threshold, too, to conserve as much battery power as possible. Anyhow, when the battery warning comes on, it has to be expected that the OSTC may shut down without further notice at any time due to depleted battery. It is therefore strongly advised to not start a dive with a battery reading below 50%.
- The color-coding of the ppO2 shown in the custom view has been aligned with the color- coding used in the ppO2 warning and attention message.
- Fixed the erratic gas needs of 999 bar when current depth is shallower than the depth of the currently indicated stop.
- OSTC TR: in custom view 'measured pressure / SAC / needed pressure': if needed pressure is > 400 bar, display will show ">400" in warning color.
- Improved detection of charging-completed.
- Gases whose ppO2 at current depth is between ppO2 max "normal" and ppO2 max deco are now color-coded in yellow while not in deco yet (they were colored red before).
- Faster display response when changing deco-related parameters.
- Changed color coding of current GF (supersaturation) value:
+ GF factors enabled: - attention (yellow) if current GF value >= GF-high value - warning (red ) if current GF value >= 100%
+ none-GF mode: - attention (yellow) if current GF value >= 90% - warning (red ) if current GF value >= 100%
=> Resulting overall indications when violating a stop depth (in none-GF mode, 90% is used for GF_high):
1) When shallower than indicated stop depth but still deeper than ceiling *): Attention on stop depth (yellow)
2) When shallower than indicated stop depth and shallower than ceiling: Warning on stop depth (red) As the current GF will be >= GF-high in this situation, additionally: Attention on current GF factor (yellow) Attention on depth (yellow, blinking)
3) When shallower than indicated stop depth and ceiling, and outside ZHL-model: Warning on stop depth (red) Warning on current GF factor (red) Warning on depth (red, blinking)
*) In GF mode, the ceiling depth is calculated at GF-high, in none-GF mode at 100% supersaturation.
- Updated calculation of ascent time:
+ When there is a ceiling but not yet a stop obligation (deco will vanish during ascent):
ascent time = current depth / ascent speed rounded up to next full minute
+ When in deco with indicated stops:
ascent time = (current depth - depth of last stop) / ascent speed rounded up to next full minute + 1 minute for each meter from depth of last stop to surface + sum of all stop times
+ when in deco with indicated stop(s) and shallower than the last stop:
ascent time = 1 minute for each meter from current depth to surface + time of the pending stop(s)
- De-cluttered and ordered dive mode custom views by topics:
1 average depth and stopwatch - all modes 2 compass - all modes 3 ppO2 sensors - CCR & pSCR only 4 sensor check - CCR mode only 5 pSCR data - pSCR mode only 6 tank pressure and SAC rate - OSTC TR only 7 gas needs for ascent - deco modes only 8 gas needs for return - cave mode only, not yet available 9 deco plan - deco modes only 10 ceiling, current GF and tissues - deco modes only 11 CNS values - deco modes only 12 ppO2, END/EAD and CNS - deco modes only 13 GF factors - deco modes only 14 clock, battery and surface pressure - all modes
deco modes = OC, CCR and pSCR
- Eliminated a use of the GF-high parameter in none-GF mode.
- Improved rounding of first stop depth.
- Improved calculation of NDL time.
- Improved and streamlined calculation of CNS values at end of dive.
- Improved switch-over from being within NDL to being in deco, and vice-versa. A stop time of ".." minutes will be shown when there is already a ceiling obligation but deco calculation reveals that it will vanish during the ascent, given the ascent speed limit is obeyed.
- Fixed a bug in the calculation of the initial ascent.
- Made overall deco calculations once more a little bit faster.
- Stabilized timebase for blinking of setpoint display.
- Improved handling of the condition when a bailout plan can not be computed due to no breathable bailout gas available.
- Upfixed alternative divemode screen layout handling, fixed message suppression and automatic custom view switching in combination with alternative layout.
- Added an option for selecting if the max. depth or the average depth shall be shown in the main divemode screen.
- Improved stability of the timebases used for calculating the average depths.
- Removed erratic NDL outputs in gauge mode.
- Fixed display of resettable dive time when it exceeds 99 minutes, 59 seconds: + up to 99 mins, 59 sec display shows minutes:seconds + after 100 mins display shows hours:minutes
- Improved energy saving by shutting down compass and accelerometer circuitry whenever compass is not shown.
- For those that like underwater navigation with compass: when the compass is shown, the temperature display will be replaced by a display of the resettable dive timer.
- When configuring a manually set gas while the dive ("gas 6"), it's display will be color-coded according to the set O2 ratio, the current depth and the ppO2 max thresholds, the latter automatically switching between normal and deco ppO2 max on dive condition. After adjustment of O2 and He ratios, the gas can be finally taken by selecting the "gas: xxx" item from the menu.
- The better gas cue is now also given when switching while the dive to the manually set gas ("gas 6"). As long as there is a regularly configured gas or diluent that fits for the current depth, a cue will be given towards this regular gas/diluent. This cue can be suppressed by setting the cued gas/dil as lost.
- The tissue graphics in dive mode now also displays the number of the leading tissue whenever the current gradient factor is > 0% or when in deco. (remaining todo: there is a light flicker in the output)
- Reworked the way the current firmware version and status (beta, release) is displayed, removed the "SP" notation.
- Known limitation: after 18 hours, 12 minutes and 16 seconds of dive time: + The average depths will show erroneous values. + The resettable dive time will wrap around to 0.
[2.98] MD5: f00ba50eb1e4ff7927aa0ec16a640b0b
- Stable Version - BUGFIX: "lost gas" was re-activated in rare cases BUGFIX: Internal deco planner did not display results in imperial units BUGFIX: CNS display was out of scale (much too high) for some cases in the logbook BUGFIX: pSCR ppO2 fixed CHANGE: Battery names in "New Battery" menu (OSTC Plus and OSTC 3 only)
[2.97] MD5: ec864820ee576841a2805227d7b39a99
- Stable Version - SP1 BUGFIX: Re-enable Sensors after sleep in PSCR mode BUGFIX: handle two deco gases configured to the same change depth CHANGE: minor italian translation update CHANGE: Sync safety stop countdown output with divetime
[2.97] MD5: 2f97a168530d2c86a43bbe382dde92ad
- Stable Version - NEW: On-the-fly Gas needs calculations for all active gases NEW: Internal deco calculator shows deco plan and gas beeds for Bailout case NEW: CNS now, CNS in xx minutes, CNS if bailout plan is used and CNS when surfaced (Including all deco stops) is shown NEW: Bailout TTS is computed in CCR mode (optionally) with gas needs for all bailout gases and all deco stops NEW: Warning if an isobaric counter diffusion occurs (also in internal planner) NEW: Warning "X-ZHL16-X" if deco model is used beyond theoretical limits NEW: Show "Deco Zone" if we are in deco and at least one tissue is off-gassing CHANGE: Internal deco routines heavily optimised for speed and code size CHANGE: Limit button sensitivity to 80% BUGFIX: Auto-Gain for newer compass versions did not work (Which decreased accuracy of heading) CHANGE: Make disabled gases darker in surface mode (Common issue for color-blind divers) CHANGE: French and Italien language updates NEW: Independent saturation/desaturation multipliers for GF and non-GF Deco modes CHANGE: Non-updated values are shown in dark blue (e.g. after a gas change) until values are valid again CHANGE: USB OSTC (OSTC 3 and OSTC cR) will enter USB mode from Menu only
[2.27] MD5: fc46b26261869dc6694fe3978766308e
- Stable Version - BUGFIX: Display of negative (°C) water temperatures NEW: One dezimal for water temperatures below 10°C BUGFIX: Battery handling in OSTC Plus hardware
[2.26] MD5: 4d547332a9feceeb1a528fefbc9279ed
- Stable Version - BUGFIX: O2 Sensor readings were not updated in fixed setpoint mode CHANGE: Minor logbook layout fix BUGFIX: "lost gas" showed current set of gases (Diluents in CC, OC in Bailout) for both "lost gas" menus NEW: Show Compass calibration results in Compass menu BUGFIX: Simulator in CC mode BUGFIX: Changing the dive mode and starting the simulator (without leaving the menu first) caused false calculations in the simulator BUGFIX: PSCR Mode "OC Gases" showed Diluents, not OC gases BUGFIX: CCR Mode ("First Diluent") was chosen based on OC "First Gas" number CHANGE: CCR Calibration gas range limited to O2% 21-25 and 95-100 to save button presses NEW: Show a warning for each sensor if the sensor is end-of-life after calibration (Less then 8mV in Air at sea level) CHANGE: Minor optimizations BUGFIX: Lost Diluent now possible in CCR and PSCR mode NEW: ppO2 blinks in sensor mode when min/max boundaries are hit CHANGE: Show actual GF (Not relative) in custom views in dive mode BUGFIX: Do not check ppO2 for disabled gases CHANGE: Apply safety margin parameters to both models (GF and non-GF) BUGFIX: Impossible fixed-ppO2 (e.g. 1,6bar in 3m) used for tissue calculations BUGFIX: Menu tree cleaned up (Exited to CCR menu from simulator settings) BUGFIX: Do not show GF in divemode for non-GF deco mode BUGFIX: Skip MOD Test for CCR in Sensor modes (OSTC cR and OSTC3 only) CHANGE: Swap positions of ppO2(O2) and ppO2(Dil) in customview 10 on screen: "left = lean" and "right = rich" BUGFIX: A wrong configured gas was suggested as "Better gas" on the configured depth even if this resulted in a ppO2 high or low condition BUGFIX: O2 as diluent in CCR caused wrong calculations (Deco, EAD, END) in less then 6m depth BUGFIX: Ignore "Toggle GF" Menu entry (in divemode) when using the non-GF deco mode BUGFIX: Minor dive mode layout fixes in CCR Mode CHANGE: Minor German language fixes NEW: Warning for Diluent beeing out of safe ppO2 range in CCR modes NEW: New Customview 9 in OSTC cR or OSTC3 shows mV readings after Sensor calibration NEW: Third and fourth logbook page per dive showing Gaslist and Setpoints in standard font size BUGFIX: several minor graphic issues in logbook fixed BUGFIX: Rare button issues in OSTC Plus hardware BUGFIX: Compass sensitivity for newer models BUGFIX: PSCR mode showed bailout gaslist instead of diluent gaslist BUGFIX: PSCR mode "Better Gas" showed bailout gases instead of diluents NEW: More customviews in surface mode for PSCR mode NEW: Last Dive customviews in surface mode with divetime, depth and interval BUGFIX: Reset to MOD in Diluent Menu did reset Setpoint change depth NEW: Two ppO2 max settings. One for travel/bottom and one for deco gases
[2.15] MD5: 1644ab15225c01e2f2e772044f6221b5
- Stable Version - NEW: Deep Sleep mode for OSTC Plus and OSTC 2 (2017) (Entered automatically) NEW: Logbook detail page in larger font (And nicer layout) CHANGE: Sleep mode current slightly reduced for all hwOS devices NEW: Logbook now records battery information NEW: Markers in internal logbook drawn as small "m" next to the profile
[2.13] MD5: a1f5efe559530da84074ebf9b513046f
- Stable Version - BUGFIX: Layout fixes in Gauge mode (German and French language only)
[2.12] MD5: 426cb47b7e79b5b6da6a50e82693440b
- Stable Version - CHANGE: Indicate "Bailout" for bailout deco plan in internal deco planer CHANGE: Easier to understand "New Battery" menu (OSTC model dependent) BUGFIX: Minor layout corrections in imperial units dive screen NEW: New Customview 11 in dive mode shows ppO2, EAD/END and CNS CHANGE: Customview 4 shows Clock, Battery Information and Tissue Information CHANGE: Show warnings either in Customview (If active) _or_ next to warning sign NEW: Show battery type in information menu (T0:3.6V AA, T1:1.5V AA, T2:3.6V/0.8A LiIon, T3:Internal 18650, T4:Internal 16650) NEW: Show battery type in surface mode next to battery voltage
[2.10] MD5: 00d22d2b2aff7dac331d40a278a7b496
- Stable Version -
NEW: Adjustable timeout for Divemode CHANGE: Firmware now split in two variants (EN/DE) and (FR/IT) NEW: New battery option for AA 3,7V rechargable (For OSTC 3) NEW: Show Uptime (Time since last firmware boot) in information menu NEW: Store more battery info into logbook memory BUGFIX: Minor text alignment fixes
[2.09]
MD5: d4aa68d2c418852adbdb57a5538f500b
- Stable Version -
BUGFIX: Compatibility with hwOS Config fixed
NEW: New hardware descriptor command 0x60 added (For PC programs)
[2.08]
MD5: 1d8b13d8ed4ae52326a521471407532f
CHANGE: Logbook marker temporally disabled in internal logbook
BUGFIX: Characters with descenders were not drawn correctly in rare cases
NEW: Support for different compass chip (Internal hardware change)
CHANGE: Language fixes
[2.07]
MD5: 9b2f71a511890dad0e5624067354a6fb
Release version for new OSTC2 (Minor internal hardware changes)
CHANGE: Remove ppO2 [Dil] from OC dive mode screen
[2.05]
MD5: 8e73ae695057856502b42e431c571d2d
- Stable Version -
NEW: Support for new logbook memory chip (minor hardware change)
BUGFIX: Button sensitivity was not reset after update in some cases
[2.04]
- Beta Version -
NEW: New Customview shows ppO2(O2) and ppO2(Diluent) during CCR mode
[2.03]
MD5: 89e0bc9bd949588e3f1845efdd9dfe1c
- Stable Version -
BUGFIX: Fix missing ccr setup menu (From 2.02)
[2.02]
MD5: 234a56fb8b9add06a9c6344dfbfe2579
- Stable Version -
BUGFIX: Fix rare issue after battery change (OSTC3 did not start properly)
[2.01]
MD5: f7908ef65e0637a0d54de4f499b3b3db
- Stable Version -
BUGFIX: Divetime >99mins was not displayed (Only OSTC2 with serial > 10500)
BUGFIX: Minor layout fixes in divemode (Dynamic gaslist and stopwatch)
BUGFIX: Minor language updates
[2.00]
MD5: e01ad26895b65097605af33e95089211
- Stable Version -
NEW: Logbook marker can be set in dive mode menu (OC only)
NEW: Logbook shows markers with small orange boxes in the profile
NEW: Lost Gas feature allows disabling gases during the dive
CHANGE: Show velocity from 5m/min or more (Ascend or descent)
BUGFIX: Make sure SP1 is always selected on start in Auto-SP mode
CHANGE: New segmented speed graph in divemode
NEW: Safety Stop can be configured (Start-, End- and reset-depth + length of stop) via PC
[1.93]
MD5: a0ee9c3854b68916445cfe62144bd157
- Stable Version -
BUGFIX: minor text allignment in CCR mode
CHANGE: fix timing issues during Bluetooth download (Bluetooth models only)
[1.92]
MD5: c99ef3ef813aba656a67929aa785698b
- Stable Version -
CHANGE: Logbook now shows end-of-dive date and time for dives made with firmware <1.92 indicated by an icon in the logbook
CHANGE: Logbook shows start-of-dive date and time for dives made with firmware >=1.92
BUGFIX: Text alignment in logbook
NEW: Show actual dive count in logbook list view (If <1000)
BUGFIX: Minor language and text aligment fixes
[1.91]
MD5: 2eb16d81d1bc7087d7f8ef576118a7ef
- Stable Version -
BUGFIX: German texts in ppo2 menu were too long for screen resulting in resulting in text display issues
[10.80] MD5: c78730c4beed14fb885b2429f5067414 CHANGE: Add voltage-based battery meter for OSTC+/PLUS when inserting batteries with unknown SOC CHANGE: Compatibility for new hardware versions CHANGE: Language updates BUGFIX: Release and "Update" dates fixed
[10.78] MD5: d8c91645fa1dd6a6823868031cd30620 CHANGE: do not show the "slow" in the alternative layout CHANGE: minor adjustment of depth position in large layout
[10.77] MD5: daaf28252b05631423b9357eaeae22ee NEW: Descent counter for Apnoe mode NEW: Dedicated surface customview #11 for Desat-Time, No-Fly and CNS FIX: NDL was shown in normal layout once deco was cleared in large layout NEW: Charge Cycle counter in Information menu CHANGE: Compatibility for new hardware versions
[10.76] MD5: 2324f02215f23e3e575b5111836e76b2 FIX: Wrong release date in 10.75 showed "Update!" message prematurely CHANGE: Compatibility for new hardware versions
[10.75] MD5: bd67e528e496bf3faa6f4b8999c69abd BUGFIX: Increase resolution of tissue pressure calculations to track very low pressure differences between ambient and tissue pressures CHANGE: OSTC with mechanical (magnetic) buttons need both buttons beeing pressed to wake up CHANGE: Support for new OSTC+ hardware with O2 sensor inputs CHANGE: Adjust max. brightness settings CHANGE: reset planning parameters to default values - only when entering the menu, thus keeping the settings between multiple calculator runs FIX: the output of the calculation results was divided into several steps, which could be interrupted in cooperative multitasking. So glitches could occur in the screen output if e.g. the TTS switched to NDL but the deco data flag vector was not updated yet. Now the compilation of all calculation results can no longer be interrupted.
[10.74] MD5: d185c7080e65e2a4106946c562ab6425 CHANGE: OSTC with mechanical (magnetic) buttons need both buttons being pressed to wake up CHANGE: minor changes in the different language versions BUGFIX: Bluetooth Reset option for 2022 OSTC sport models fixed CHANGE: Compatibility for new hardware versions
[10.73] MD5: 39e59f652a6c0116934d97ff57d4a45f BUGFIX: Properly update desaturation time and tissue data after battery change (OSTC with user-replaceable batteries only) NEW: Option to suppress non-critical warnings in dive mode CHANGE: Do not present gas6 option in alternative layout (Switch to normal layout in order to configure the gas 6 during the dive) CHANGE: Do not show RX portions of tank setup menu when there is no RX hardware CHANGE: Low-level code improvements for performance
[10.72] MD5: a4202eb0df83dd2a593dbbcccabc62be NEW: Support for current hardware version of OSTC 2, plus and Sport - a Reset Bluetooth from the Reset Menu might be required for BLE/Bluetooth 4.0 to be enabled
[10.71] MD5: 84bf439ba7ecfc6463f29535370e04c3 BUGFIX: Sensor detection in OSTC plus could fail for some hardware versions BUGFIX: calculate time/date of the end of the dive in logbook screen correctly for dives with a lot of surface time/many descents NEW: Different brightness settings for dive and surface mode NEW: minor changes in the different language versions BUGFIX: Reduce sleep mode current
[10.70] MD5: 0f7c9081faebc4f1e5f983395e1f0854 NEW: Support for new pressure sensor type in OSTC 2 and plus NEW: Several changes in the different language versions CHANGE: Tweak gas use routine to work with unplanned changes (Switching to inactive gases) BUGFIX: Pulsing of backlight under some conditions fixed NEW: Large (Single line) menu in dive mode when large layout is selected
[10.68] MD5: 9a611ba6ebe9d1d98917257dd5b5f673 NEW: Support for current hardware version of OSTC 2 and plus FIX: Abort on unknown parameter in comm mode CHANGE: Several small language fixes CHANGE: increase battery safety margins for Saft (T0) and 16650 batteries (T4)
[10.67] MD5: a6881d59859b493b9fcc25a51936f121 BUGFIX: Surface pressure compensation (zero m reference) could be delayed or stuck to old reference value BUGFIX: configuring deko gases via the mobile Apps was not possible CHANGE: French language fixes
[10.66] MD5: 33b70935590bc0c081b25d759e8dda34 BUGFIX: Improved calculation accuracy of the initial ascent. Remark: this will have a slight impact on the resulting deco schedule compared to firmware 10.64. CHANGE: The menu system around setting up the dive mode & settings has been decluttered. All settings are now sorted into the groups dive setup, deco setup, SAC (gas needs) setup, ppO2 setup and stops & depths setup. NEW: There is a new option "Swap on empty" in Dive Setup -> SAC Setup. It is only effective if "CalcGas(B/O)" is switched on, too. If both options are switched on, the deco calculation will switch to another tank (i.e. gas) once the tank of the current gas is calculated to be used up. This function can be used to automatically calculate a contingency in case of running out of a deco gas, as the deco calculation will then continue to calculate a deco making use of the spares from the another gases carried. Another application is with two or more tanks holding the same gas (i.e. independent double configuration, side-mount), as the calculations will then take the cumulative amount of gas carried into account before raising a gas needs attention or alarm. NEW: For dives done on firmware >= 10.66 the logbook will have one more page showing the tissue pressures and supersaturation levels as of at the end of dive (i.e. when surfacing). NEW: New option to acknowledge the most recent warning in dive mode (Left press -> Ackn?) BUGFIX: Hardened all USB/Bluetooth communication against data losses and timeouts NEW: A new Firmware Recovery Feature has been added: the currently active firmware can be backed-up and restored later on while other firmwares have been loaded thereafter. The feature is accessible via Settings -> System Settings -> Reset Menu -> Reboot and becomes available with the first firmware load after the 10.66 (or later) is already on the unit. BUGFIX: During loading of a new firmware the clock will not loose time any more (on old firmware it became late by about 15 sec on each firmware update). CHANGE: When run from a 3.6 V battery (either replaceable or built-in), the surface mode timeout is now extended to 4 minutes before going to sleep mode. If the OSTC is run from 1.5 V disposables, the timeout remains at the previous 90 seconds to save on battery runtime. NEW: Updates OSTC 2 TR computers to RX-Firmware 1.40
[10.64] MD5: d7cb426cc40c3f6573d4b40be5d90513 BUGFIX: "Sticky" button behaviour on some hardware versions (Only OSTC 2 (2017), TR and OSTC plus)
[10.63] MD5: a88102fed4954b6371f235cbb0145b61 BUGFIX: Add surface part at end of dive to surface interval properly BUGFIX: Average depth in logbook did not took salinity setting into account CHANGE: Change color of temperature values in logbook to yellow
[10.62] MD5: 3ebe9959476337ce4eaf1747ac88dbb6 BUGFIX: Hardware versions 13-xx-xx and 58-xx-xx could hang up with 10.56 or later
[10.60] MD5: c597bdb7fd2499d0e390e1aaedb0cbce BUGFIX: Surface mode could freeze in some hardware versions BUGFIX: Potential issue with Bluetooth in older OSTC sport models CHANGE: Default language in EN/DE version is English again
[10.58] MD5: ecc3920cfee8b21720e6131f126d0851 BUGFIX: Version number was not shown in main screen BUGFIX: Button function could be toggled on charger
[10.57] MD5: 52eefadd6bd7ef05032ab0f151100644 BUGFIX: NDL in big font display BUGFIX: Bluetooth mode in old OSTC sport (Red buttons)
[10.56] MD5: d1585f659a64c57f4dbf6a222277cbef NEW: Five gases instead of three NEW: Optional, 2nd Tissue graphic with markers for GF_low, GF_high and M-Value NEW: Complete new Deco Planner and OSTC Simulator NEW: 2nd Deco plan can calculate "Gas needs" (Optional) for all gases in real-time NEW: Optional "Gas change time" and selectable extended stops (Shifting the gas change to the first real deco stop) NEW: Configurable ascend speed NEW: Support for more hardware versions (OSTC sport and 2 TR) NEW: 2nd Layout (With larger fonts and slightly less information) CHANGE: Deco plan is updated much faster NEW: Information menu shows hardware version
[10.53] MD5: 2e2d691b89479934d7d433bb4a2da7cb BUGFIX: New battery menu was not visible after battery insertion on certain hardware versions
[10.52]
MD5: c8493b112d7686c5578b7f9479782ec0 NEW: Updates OSTC 2 TR computers to RX-Firmware 1.37 BUGFIX: Fix (another) critical issue with compass routine
[10.51]
MD5: a5fbee144b7ff14cc0053a7b6f3614a6 CHANGE: Battery selection menu simplified BUGFIX: Minor language and layout corrections
[10.50]
MD5: d8a8f44d4465a114c96712cb78d49d0d BUGFIX: Too high sleep mode current in OSTC 2 and OSTC plus fixed NEW: Updates OSTC 2 TR computers to RX-Firmware 1.36 CHANGE: Faster rendering of fonts and logbook graphics NEW: Show RX-firmware in custom view in surface mode NEW: Option to log Apnea dives in the logbook BUGFIX: Fix issue with compass routine CHANGE: Use hPa instead of mbar for surface pressure
[10.49]
MD5: 945ec4a1ce0ce61cd795c75a865a2d1a NEW: Updates OSTC 2 TR computers to RX-Firmware 1.32 NEW: Option to enable/disable the RX circuity (TR hardware only) CHANGE: Default conservatism now 30/85 as in the hwOS TECH BUGFIX: 10.45 showed "Update installed" after any power on reset BUGFIX: In very rare cases, the gas setup screen could freeze in surface mode
[10.45]
MD5: 1421bdd102c8fbec5f909451aa36818e CHANGE: Updates OSTC 2 TR computers to RX-Firmware 1.31 BUGFIX: One dezimal for water temperatures below 10°C BUGFIX: St.By-Current for OSTC 2 TR computers was higher then expected CHANGE: Minor language updates
[10.42]
MD5: b80fc8a6605729ef676d510b02c1edca BUGFIX: Auto-Gain for newer compass versions did not work (Which decreased accuracy of heading) CHANGE: Make disabled gases darker in surface mode (Common issue for color-blind divers)
[10.41]
MD5: a81cc91f2f67abbaf5754865719d8a25 NEW: Support for OSTC 2 TR hardware NEW: Support for new compass electronics (internal hardware change)
[10.40]
MD5: d50c59e956ee954e7e298d16682a0ec8 BUGFIX: Display of negative (°C) water temperatures NEW: One dezimal for water temperatures below 10°C BUGFIX: Battery handling in OSTC Plus hardware NEW: Count dives during Apnoe mode (Shown next to Total) NEW: Second ppO2 setting for deco gases
[10.39]
MD5: 83d803a7cddebf737df8a40ae062eaa5 NEW: Show Compass calibration results in Compass menu BUGFIX: Logbook-Offset display in menu
[10.38]
MD5: 5b9155f0a567e3f8c43360734904b20e CHANGE: Show actual GF (Not relative) in dive mode BUGFIX: Do not check ppO2 for disabled gases CHANGE: Apply safety margin parameters to both models (GF and non-GF) NEW: Additional custom view in dive mode: ppO2, Ceiling and current GF NEW: Last dive custom view with divetime, max. depth and interval NEW: "Reboot" and "Reset Deco" option in Reset menu BUGFIX: Minor language fixes in German and French
[10.37]
MD5: d510b0f6632d4402f73b154bb2b60b65 NEW: 2nd and 3rd logbook details page re-designed BUGFIX: several minor graphic issues in logbook fixed BUGFIX: Rare button issues in OSTC Plus hardware
[10.35]
MD5: f685aff34796f70eb167e87f7ae31934 BUGFIX: Decoplan with a lot of deco caused minor graphic errors in dive mode Bugfix: More then one marker shown deleted profile NEW: Show battery % in logbook (For dives made with 10.34 or newer)
[10.34]
MD5: 72f03dfdcd561152ebba8413229d0a64 NEW: Deep Sleep mode for OSTC Plus and OSTC 2 (2017) (Entered automatically) NEW: Logbook detail page in larger font (And nicer layout) CHANGE: Sleep mode current slightly reduced NEW: Logbook now records battery information NEW: Show time since last dive in surface mode NEW: Markers in internal logbook drawn as small "m" next to the profile
[10.33]
MD5: 63e63b2292c4cc1387dd2c63f197aed0 NEW: Dive mode menu has option to manually quit the dive when in <1m depth BUGFIX: Surface mode decoplaner did not show stop lengths on new OSTC plus BUGFIX: Layout fixes in Apnea mode (Bottom line)
[10.32]
MD5: f93388ef748ec56ef5c5529e1fffd739 CHANGE: Simulator max depth now 70m NEW: New Customview 5 in dive mode shows ppO2, EAD/MOD and CNS CHANGE: Customview 3 shows Clock, Battery Information and Tissue Information CHANGE: Show warnings either in Customview (If active) _or_ next to warning sign NEW: Show battery type in information menu (T0:1.5V AA, T1:3.6V AA, T2:3.6V/0.8A LiIon, T3:Internal 18650, T4:Internal 16650) NEW: Show battery type in surface mode next to battery voltage
[10.31]
MD5: 186edb0ae3bc27b1bb3e183e4310aba9 BUGFIX: Minor layout corrections in imperial units dive screen BUGFIX: Battery menu and companion compatibilty for non-BLE Sports
[10.30]
MD5: 77c984d69de345aa617f0762e2ba71a1 BUGFIX: Compatibility with "hwOS Config" fixed NEW: New hardware descriptor command 0x60 added (For PC programs) NEW: Support for 0.8Ah rechargable battery (3,6V) NEW: Refined battery meter code NEW: Adjustable timeout for Divemode CHANGE: Several language fixes NEW: Show MOD in all Gas Setup related submenus NEW: Show Uptime (Time since last firmware boot) in information menu NEW: Store more battery info into logbook memory CHANGE: Easier to understand "New Battery" menu
[10.26]
MD5: aa95cfa15dda0ce6d973897627d072c9
NEW: Support for new logbook memory chip (minor hardware change)
CHANGE: Large font for current gas in gas setup
NEW: Allow GF settings configured through PC
[10.25]
MD5: 4708bf61070576443f4f7fe65c57863a
BUGFIX: Fix missing gas setup (From 10.24)
NEW: Safety Stop can be enabled/disabled from the menu
[10.24]
MD5: f85b96e5406fac11def528768a6b7771
BUGFIX: Fix rare issue after battery change (OSTC sport did not start properly)
[10.23]
MD5: 609d722c9bb8599aa908b92ec15cb75a
CHANGE: Show velocity from 3m/min or more (Ascend or descent)
NEW: Segmented speed graph in divemode (optional)
NEW: Variable speed (7-20m/min) depending on depth (optional)
NEW: Safety Stop can be configured (Start-, End- and reset-depth + length of stop) via PC
NEW: Logbook marker can be set in dive mode menu
NEW: Logbook shows markers with small orange boxes in the profile
[10.22]
MD5: 83fa30f8ffdaf3c4c8d8f155291348b1
CHANGE: Logbook now shows end-of-dive date and time for dives made with firmware <10.22 indicated by an icon in the logbook
CHANGE: Logbook shows start-of-dive date and time for dives made with firmware >=10.22
BUGFIX: Text alignment in logbook
NEW: Show actual dive count in logbook list view (If <1000)
BUGFIX: Minor language and text aligment fixes
[10.21]
MD5: a730b736ce322aa216810c35e9ade9b9
CHANGE: button hold-down will increase values or move the cursor automatically (again)
BUGFIX: +5min for stopwatch during simulation did not work
BUGFIX: Bluetooth communications issues
[10.20]
MD5: 8e445d06ad5caf5fafe6f7b36ebe41c2
NEW: Option to rotate the screen
BUGFIX: BLE timings for MAC issues
BUGFIX: Battery consumption calculation in sleep mode (3,6V battery only)
NEW: Bearing can be set in surface mode
[10.19]
MD5: 3d212302a810f40097954ebac0f5929f
CHANGE: Custom GF high range increased to 45-95 NEW: Quit Simulator automatically when starting a real dive BUGFIX: Auto-Brightness clipped to lowest settings in bright sunlight on some devices
[10.18] MD5: 94f07a4d736cb2a1555a1faf127546b9
- Stable Version - NEW: Deco planer computes gas consumption for all gases CHANGE: Battery warning adjusted
[10.17] MD5: 180a23d1a92b94e5da08e4c85bd42389
- Stable Version - BUGFIX: Fix PC download issue for dives made with 10.16 firmware
[10.16] MD5: f8101514a7e66dde8aae0a76fcd65c40
- Stable Version - CHANGE: Range of Custom GF_lo now from 20 to 95 CHANGE: Automatically abort connection fail after 2mins BUGFIX: Fast Gas change near the ppO2 limit could cause switching to a non-available Gas #0 BUGFIX: There was a 1:4096 chance that a portion of a dive was not stored correctly resulting in download issues
NEW: Logbook shows markers with small orange boxes in the profile
New in 3.12:
Beta Release
BUGFIX: Minor layout fix (Battery warning in divemode)
CHANGE: Color-code battery display in surface mode (Charge, Full, Normal)
New in 3.11: BUGFIX: First Diluent and SP Mode used same EEPROM location
New in 3.10: Stable Release
New in 3.05: Beta Release NEW: Quit Simulator automatically when starting a real dive CHANGE: Battery percent based on ON-Time instead of battery voltage
New in 3.04: Beta Release BUGFIX: Fix licence in German BUGFIX: Fix minor layout bugs in surface mode NEW: Auto Setpoint switch function (CC Modes)
New in 3.03: Stable Release BUGFIX: 1st line in logbook was not displayed in rare cases (2C hardware)
New in 3.02: Stable Release BUGFIX: Divetime had unwanted . behind the minutes
New in 3.01: Stable Release BUGFIX: Entry time in logbook when dive was around midnight BUGFIX: Show manually set O2 (Gas 6) correctly BUGFIX: Show dives with >999mins divetime correctly
New in 3.00: Stable Release BUGFIX: Fix color codes 192-223 (Mk.2 and 2N only)
New in 2.95: BETA Version BUGFIX: Surface interval was paused during simulator BUGFIX: False Bailout and Gas 6 flags in logbook BUGFIX: Color of Menu? in divemode
New in 2.94: BETA Version BUGFIX: False bailout flag in logbook NEW: On-Time counter for better battery information NEW: Store useage timer in logbook header (Byte 54, see documentation) NEW: CF74: Battery Timeout [min] - Battery symbol will blink if the OSTC was longer in active mode (since the last _full_ charge) then CF74. Default=1800 (30hours)
New in 2.93: BETA Version NEW: Show Gas change countdown if CF55>0 CHANGE: Graphical velocity on by default (CF60=1) NEW: Ceiling display (GF_hi based) in divemode CHANGE: No turkish language support anymore BUGFIX: Gas volume computation when using several travel mixes
New in 2.91: BETA Version New: Show bailout event in internal logbook
New in 2.90: Stable Release BUGFIX: CNS calculation in decoplan should track gas (no marked changes anymore)
New in 2.81: BUGFIX: Show bailout list if first bailout gas <> gas 1 BUGFIX: Italian language fix (Divemode menu) BUGFIX: Gas change depth display in divemode menu (OSTC 2C only)
New in 2.80: Stable Release
New in 2.75: BETA Version - Do NOT use for diving BUGFIX: ppO2 display in PSCR Mode
New in 2.74: BETA Version - Do NOT use for diving BUGFIX: remove ghost image (On 2C only) during first second in sleep mode CHANGE: Remove CF55 from decolist TODO: show gas change stops different from decostops BUGFIX: FTTS>9min in OSTC 2C hardware NEW: Show the bailout list in surfacemode (CC Modes) CHANGE: Faster button response
V 2.10 stable CHG: High-low sensor voting FIX: bailout menu in dive mode FIX: USB mode file system access NEW: USB mode watch dog NEW: time and date menu after hard reset NEW: fast boot to dive mode CHG: return to CCR after Bailout dive NEW: Calibrate info on surface screen
V 2.09 stable FIX: custom view decolists
V 2.08 stable NEW: up to 30 longer standby time
V 2.07 stable FIX: O2 display of inactive sensors in surfmode FIX: USB timeout FIX: power consumption in standby after first start FIX: menu colors in divemode FIX: Gaslist selection on Bailout start in divemode NEW: speed optimization level 2
V 2.06 stable FIX: O2 and Scrubber display in dive mode CHANGE: O2 calibration range extended CHANGE: menu name for open circuit gas changes
V 2.05 stable BUG: O2 sensors display not in seperate lines. Please use V2.02 for O2 monitioring prior to V2.06 release.
CHANGE: First Gas instead of Bottom Gas in menu FIX: stop watch FIX: end of dive
V 2.02 stable CHANGE: start divemode exit counter if depth < 1.0 meter and
V 2.01 stable FIX: stability with 1. generation motherboards FIX: deco-info with 0 minutes did not disappear if TTS > 0 minutes
V 2.0 stable NEW: VPM-B with GF NEW: Bühlmann GF ( hw Version 3.0) NEW: table mode
V 1.98 beta DR5 redone. CHANGE: new deco models NEW: table mode CHANGE: menu strucure surface CHANGE: USB connectivity CHANGE: menu structure dive NEW: Future TTS NEW: ceiling limit NEW: brightness level 4 CHANGE: gas changes seperate for TRAVEL / DECO / BOTTOM CHANGE: custom views in surface mode CHANGE: logbook appearance CHANGE: USB ends to standby CHANGE: conservatism saturation / desaturation removed CHANGE: decoplanner deactivated CHANGE: no CCR in beta CHANGE: snake deactived
INSTALL MANUAL: Unpack to DR5 root directory . as some .system files will be changed for proper screen layout
V 1..60 stable FIX: firmware old status KNOWN ISSUES (20.June 2013): surface-decoplanner with fixed setpoints has faulty output
V 1..50 stable FIX: battery status FIX: snake below 30 mtr.
V 1.32 stable ( V1.30 build 1.32 ) FIX: gaschange warnings now based on ppO2 stop limits instead of ppO2 attention values
V 1.31 stable CHANGE: custom I 'warnings' II 'core' back again in Dive Setup CHANGE: depth without leading zero CHANGE: ppO2 out of 0.2 to 1.60 range with 'STOP' warning sign
V 1.30 stable FIX: UDDF 3.1 logbook CHANGE: warn system during dive known issues: battery charging - green LED @ 70
V 1.22 stable FIX: Logbuchspeicherung NEW: leicht veränderter black skin
V 1.20 stable (release 31.01.2012) NEW: Deaktivierung und Reaktivierung von einzelnen Gaswechseln im Tauchmodus NEW: individuelle An-/Abschaltung von defekten O2 Sensoren im Tauchmodus NEW: Kalk/Scrubber Uhr
NEW: direct config via PC NEW: UDDF 3.1 mit CCR und ppO2 Infos in der Logbuch Datei NEW: Automatische Installation von Firmware Updates NEW: intelligenter USB Modus
NEW: vorbereitet für digital I/O
NEW: black skin
FIX: Anzeigen im Tauchmodus FIX: Seriennummer Auswertung