20010 hwOS - OSTC 4 (Version 1.4.7)









History

[1.4.7] with RTE 1.70

NEW: "Saturation" replaces "Current GF", shows percentage of resulting GF high in GF-deco mode
CHG: Replace mbar with hPa in surface mode and logbook
FIX: CNS logging had unexpected values in the first minute
FIX: Language updates
FIX: Show all dive modes in surface mode (And not only CCR and OC)
FIX: Lags with screen freeze in dive mode fixed
FIX: In rare cases the OSTC4 did not power down correctly for sleep mode
FIX: Average depth was slightly off
FIX: Sync max. Depth and Depth properly
CHG: Intensive code cleanup and review, change to free GCC compiler
NEW: Full code release: https://bitbucket.org/heinrichsweikamp/ostc4/wiki/Home
FIX: highlight the menu underline correctly on selected state in dive mode
NEW: Option to Flip the screen
FIX: Several minor layout corrections in dive mode
NEW: New implementation for ceiling (identical to hwOS 2 code)

[1.3.5] with RTE 1.06

CHG: hardware support for newer models
CHG: battery percent display in surfacemode (Not voltage)
FIX: language updates

[1.3.0] with RTE 1.01

NEW: apnea mode
NEW: gauge mode (including deco stop display of deco system in background)
NEW: Average Depth and Timer in big font mode
NEW: compass bearing stored
NEW: extra-low cave brightness configuration and ultra-bright setting
NEW: extended button control and factory reset option via bluetooth
CHG: bluetooth active on system start
FIX: gas consumption calculation
CHG: small battery voltage display in surface mode

[1.2.6] with RTE 0.98

NEW: feet now everywhere in the displays during the dive
FIX: futureTTS was always calculating 5 minutes independently from settings
FIX: warnings for ppO2 max and ppO2 min
FIX: text corrections
FIX: button settings internal handling redone
FIX: Desaturation Time and NoFly Time didn't show days.

[1.2.1]

FIX: customview header text
CHG: overview added as optional on/off in dive menu

[1.2.0]

CHG: duration of dive is now total time minus all time close to surface
NEW: CCR with sensors has 10 minutes timeout instead of 2 minutes like in other modes
FIX: button reset on start-up after updating to firmware 1.1.8
NEW: added ascent and descent rate in (small) numbers
CHG: failsafe if computer is turned on during flight (880 mbar limit instead of 700 mbar)
NEW: most center custom views can be turned on and off during dive (new menu in dive mode)
FIX: temperature graph in logbook
NEW: button sensitivity overdrive with 105% and 110% now available
FIX: helium desaturion time in logbook entry

[1.1.8]

FIX: Hardware driver issues in 1.1.2
FIX: Logbook Temperature Graph core redone
NEW: Set Marker in Divemode
CHG: Surface Time calculation now based on internal clock
NEW: Battery Status will be to set to last know value after RTE update

[1.1.2]

FIX: Multiple Deco Gas Changes
FIX: Automatic Firmware Update after RTE update (for upcoming updates)
NEW: Individual Button Offset
CHG: Update of some hardware drivers
FIX: readLimits for external software

[1.1.1]

FIX: button sensitivity configuration via external software
FIX: settings warnings in surface screen
FIX: minor fixes in external software communication


[1.1.0]

NEW: Deco Planner gas consumption
NEW. Langue Français
FIX: 0x4C prompt for unknown commands
FIX: VPM ceiling
FIX: smaller fixes (bluetooth, text, fallback times)
NEW: command to distinguish standard and Bonex version
NEW: BONEX design
CHG: interface to OSTC Companion, OTSC Tools and others
FIX: custom view limits
NEW: compass calibration stored on reset (RTE)

[1.0.11]

NEW: compass damping
CHG: compass design

[1.0.10]

FIX: read settings command (for external software)
FIX: menu system for Deco1 and Sys2

[1.0.8]

FIX: dive start time in export to DivingLog, Subsurface and more (all dives)
FIX: deco / NDL status in logbook recording (new dives only)

[1.0.7]

FIX: brightness adjustments
FIX: temperature graph scaling in logbook
FIX: trimix gases text in logbook
CHG: lower limit set for no fly time
CHG: start of dive mode is now at one meter if computer is running
CHG: divetime less than one minute does not change no fly time and time since last dive
FIX: NDL calculation information after deco dive with GF algorithm
ADD: improved support for external communication with OSTC Companion

Write Your Comment

x